Sign In | Join Free | My fnxradio.com
fnxradio.com
Products
Search by Category
Home > Industrial Controls >

4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke

Categories Genset Diesel Generator
Place of Origin: China
Brand Name: GSKA
Model Number: JP- P100E
MOQ: 20-30 pieces
Price: Negotiable
Packaging Details: Standard plywood and wood package.the actual package size against goods size and handle requires.
Delivery Time: 3-5 days on receipt of official sales contract
Payment Terms: L/C,D/P,D/A, Alipay, West Union, TT. Cash,Paypal
Supply Ability: 500 pieces per Month
Port:: HongKong or ShenZhen,ShangHai,Dalian as required
CertifiCAT-partsion: CE/RoHs/ISO9001
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke


    1, Generating Set Model: JPP100E

    2, Engine Make & Model:Perkins 1006TG1A

    3,Alternator Model:LL3014B

    3, Circuit Breaker Type:3 Pole MCB / 3 Pole MCCB

    4, Frequency:50 Hz / 60 Hz

    5,Cycle: 4 Stroke

    6, Engine Speed:1800 rpm

    7, Cooling Method: Water

    8, Governing Type: Electronic

    9, Output Type: AC Three Phase

    10,Base Frame Type:Heavy Duty FabriCAT-parts-partsed Steel


    Output Ratings

    Generating Set Model

    JPP100E Prime Standby

    380-415V, 50 Hz

    90.0 kVA 100.0 kVA

    72.0 kW 80.0 kW

    480V, 60 Hz

    110.0 kVA 120.0 kVA

    88.0 kW 96.0 kW

    • Refer to ratings definitions on page 4.

    Ratings at 0.8 power factor.


    Technical Data

    Engine Make & Model:

    Perkins 1006TG1A

    Alternator Model:

    LL3014B

    Base Frame Type:

    Heavy Duty FabriCAT-parts-partsed Steel

    Circuit Breaker Type:

    3 Pole MCB / 3 Pole MCCB

    Frequency:

    50 Hz 60 Hz

    Engine Speed: RPM

    1500 1800

    Fuel Tank Capacity: litres (US gal)

    230 (60.8)

    Fuel Consumption: P90 l/hr (US gal/hr)

    20.7 (5.5) 26.1 (6.9)

    Fuel Consumption: P100E l/hr (US gal/hr)

    23.1 (6.1) 28.3 (7.5)

    P90 / P100E


    Engine Technical Data


    Physical Data


    Manufacturer: Perkins

    Model: 1006TG1A

    No. of Cylinders/Alignment: 6 / In Line

    Cycle: 4 Stroke

    Induction: Turbocharged

    Cooling Method: Water

    Governing Type: Mechanical Governing

    Class: ISO 8528 G2

    Compression Ratio: 16.0:1

    Displacement: l (cu.in) 6.0 (365.5)

    Bore/Stroke: mm (in) 100.0 (3.9)/127.0 (5.0)

    Moment of Inertia: kg m² (lb. in²) 1.61 (5502)

    Engine Electrical System:

    -Voltage/Ground: 12/Negative

    -Battery Charger Amps: 55

    Weight: kg (lb) - Dry: 586 (1292)

    - Wet: 623 (1373)


    Air System


    Air Filter Type: Replaceable Element

    Combustion Air Flow:m³/min (cfm)

    -Standby: 5.6 (198) 7.9 (279)

    -Prime: 5.2 (184) 7.5 (265)

    Max. Combustion Air Intake Restriction: kPa (in H2O) 5.0 (20.1) 5.0 (20.1)

    Radiator Cooling Air Flow:m³/min (cfm)

    192.0 (6780) 244.0 (8617)

    External Restriction to Cooling Air Flow: Pa (in H2O) 125 (0.5) 125 (0.5)


    Cooling System 50 Hz 60 Hz


    Cooling System Capacity:l (US gal) 27.7 (7.3) 27.7 (7.3)

    Water Pump Type: Centrifugal

    Heat Rejected to Water & Lube Oil: kW (Btu/min)

    -Standby: 61.4 (3492) 76.4 (4345)

    -Prime: 54.4 (3094) 69.1 (3930)

    Heat Radiation to Room:kW (Btu/min)

    -Standby: 39.9 (2269) 39.7 (2258)

    -Prime: 32.4 (1843) 31.0 (1763)

    Radiator Fan Load: kW (hp) 2.8 (3.8) 4.9 (6.6)

    Cooling system designed to operate in ambient conditions up to 50°C (122°F).

    Contact your local FG Wilson dealer for power ratings at specific site conditions.


    Performance 50 Hz 60 Hz


    Engine Speed: RPM 1500 1800

    Gross Engine Power: kW (hp)


    -Standby: 96.0 (129.0) 113.0 (152.0)

    -Prime: 87.0 (117.0) 102.7 (138.0)

    BMEP: kPa (psi)

    -Standby: 1283.0 (186.1) 1259.0 (182.6)

    -Prime: 1163.0 (168.7) 1144.0 (165.9)

    Regenerative Power: kW 12.6 16.2


    LubriCAT-parts-partsion System


    Oil Filter Type: Spin-On, Full Flow

    Total Oil Capacity l (US gal): 16.1 (4.3)

    Oil Pan l (US gal): 13.1 (3.5)

    Oil Type: AP1CD 15W-40

    Cooling Method: Water


    Fuel System


    Fuel Filter Type: Replaceable Element

    Recommended Fuel: Class A2 Diesel

    Fuel Consumption: l/hr (US gal/hr)

    110% 100% 75% 50% Load Load Load Load

    P90

    50 Hz 23.1 (6.1) 20.7 (5.5) 15.7 (4.1) 11.1 (2.9)


    60 Hz 28.3 (7.5) 26.1 (6.9) 20.0 (5.3) 14.4 (3.8)


    P100E

    50 Hz 23.1 (6.1) 17.3 (4.6) 12.1 (3.2)

    60 Hz 28.3 (7.5) 21.6 (5.7) 15.4 (4.1)

    (based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869, Class A2)


    Exhaust System 50 Hz 60 Hz


    Silencer Type: Level 1

    Silencer Model & Qty: SD80 (1)

    Pressure Drop Across Silencer System: kPa (in Hg) 0.00 (0.000) 0.00 (0.000)

    Silencer Noise Reduction Level: dB 18 18

    Max. Allowable Back Pressure: kPa (in. Hg) 6.0 (1.8) 6.0 (1.8)

    Exhaust Gas Flow:

    m³/min (cfm)

    -Standby: 16.8 (593) 22.5 (795)

    -Prime: 14.9 (526) 20.9 (738)

    Exhaust Gas Temperature: °C (°F)

    m³/min (cfm)

    -Standby: 584 (1083) 569 (1057)

    -Prime: 546 (1014) 538 (1001)

    P90 / P100E


    Alternator Performance Data



    Data Item

    50 Hz 60 Hz

    415/

    240V

    400/230V

    230/115V

    200/115V

    380/220V

    220/110V

    220

    /127V

    480/277V

    240/139V

    380/220V

    220/110V

    240/120V

    208/120V

    230/

    115V

    440/254V

    220/127V


    Motor Starting Capability* kVA


    187


    176


    160


    208


    206


    136


    160


    149


    177

    Short Circuit Capacity** %

    300

    300

    300

    300

    300

    300

    300

    300

    300

    Reactances: Per Unit

    Xd X'd X''d


    2.880

    0.110

    0.067


    3.100

    0.120

    0.072


    3.430

    0.130

    0.080


    2.560

    0.100

    0.060


    3.150

    0.120

    0.073


    5.030

    0.200

    0.117


    4.200

    0.160

    0.098


    4.540

    0.180

    0.106


    3.750

    0.150

    0.087


    Reactances shown are applicable to prime ratings

    • Based on 30% voltage dip. Improved motor starting capability is available with optional Permanent Magnet generator or AREP excitation.

    ** With optional Permanent Magnet generator or AREP excitation.


    Alternator Technical Data


    Physical Data Operating Data

    Manufacturer: FG WILSON

    Overspeed: RPM 2250

    Model: LL3014B

    Voltage Regulation (steady state) (%): + /- 0.5

    No. of Bearings: 1

    Wave Form NEMA = TIF: 50

    Insulation Class: H

    Wave Form IEC = THF: 2.0%

    Winding Pitch Code:2/3 - 6

    Total Harmonic Content LL/LN: 4.0%

    Wires: 12

    Supression is in line with European Standard

    Radio Interference: EN61000-6

    Ingress Protection Rating: IP23

    Radiant Heat: kW (Btu/min)

    -50 Hz: 9.0 (512)

    -60 Hz: 11.1 (631)

    Excitation System: SHUNT

    AVR Model: R230

    P90 / P100E



    Technical Data


    3 Phase Ratings and Performance at 50 Hz, 1500 RPM


    3 Phase Ratings and Performance at 60 Hz, 1800 RPM




    Voltage Prime Model Standby Model Voltage Prime Model Standby Model

    P90 P100E P90 P100E


    kVA kW

    kVA kW


    kVA kW

    kVA kW

    415/240V

    90.0 72.0

    100.0 80.0

    480/277V

    110.0 88.0

    120.0 96.0

    400/230V

    90.0 72.0

    100.0 80.0

    220/127V

    110.0 88.0

    120.0 96.0

    380/220V

    90.0 72.0

    100.0 80.0

    380/220V

    110.0 88.0

    120.0 96.0

    230/115V

    90.0 72.0

    100.0 80.0

    240/120V

    110.0 88.0

    120.0 96.0

    220/127V

    90.0 72.0

    100.0 80.0

    230/115V

    110.0 88.0

    120.0 96.0

    220/110V

    90.0 72.0

    100.0 80.0

    440/254V

    110.0 88.0

    120.0 96.0

    200/115V

    90.0 72.0

    100.0 80.0

    220/110V

    110.0 88.0

    120.0 96.0




    208/120V

    110.0 88.0

    120.0 96.0




    230/115V

    110.0 88.0

    120.0 96.0



    Definitions

    Standby Rating


    These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3).



    Prime Rating


    These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.



    Standard Reference Conditions


    Note: Standard reference conditions 27°C (80°F) Air Inlet Temp, 152.4m (500ft) A.S.L. 60% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.




    Weights and Dimensions


    Weights: kg (lb) Dimensions: mm (in)



    Net (+ lube oil)


    1240 (2734)


    Length


    2481 (97.7)

    Wet (+ lube oil & coolant)

    1260 (2778)

    Width

    746 (29.4)

    Fuel, lube oil & coolant

    1454 (3206)

    Height

    1435 (56.5)



    General Data


    Documents


    A full set of operation and maintenance manuals, circuit wiring diagrams, and commissioning/fault finding instruction leaflets.



    Generating Set Standards


    The equipment meets the following standards:


    Warranty


    All equipment carries full manufacturer's warranty.


    Quality 4 Stroke 80 kW Diesel Generator , JPP100E , 100 kva , 4 Stroke for sale
    Send your message to this supplier
     
    *From:
    *To: Guangdong ALI Testing Equipment Co,.Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0