Sign In | Join Free | My fnxradio.com
fnxradio.com
Products
Search by Category
Home > Industrial Air Conditioners >

800 Watt Outdoor Cabinet Air Conditioner For Outdoor Telecom Shelter / Base Station

Categories Outdoor Cabinet Air Conditioner
Brand Name: CYNRIN
Model Number: CCA015SA
Certification: CE,EMC,RoHS,CCC
Place of Origin: CHINA
MOQ: 1 sets
Price: USD300~3999 unit
Payment Terms: T/T, D/A, D/P, L/C, Western Union, MoneyGram
Supply Ability: 10000 sets per Month
Delivery Time: 14 work days after payment
Packaging Details: Wooden case package.
Product name: Outdoor Telecom Shelter Air Conditioner
Cooling capacity: 800W
Operation voltage: 220VAC
Mounting: Wall / door Mount
IP: IP55
Warning output: Dry Contact
Capacity (btu): 7800
Dimension(mm): 352*175*583mm
Refrigerant: R134a
Application: Outdoor Telecom Shelter, Telecom Room,Telecom Base Station
Working enviroment: -15 °C To +55 °C
Function: Cooling /Heating
Noise: 65dB(A)
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    800 Watt Outdoor Cabinet Air Conditioner For Outdoor Telecom Shelter / Base Station

    800W AC220V Outdoor Cabinet Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station

    Product Characteristic


    1. Description


    The AC Air Conditioner is a full automation temperature control product. It uses intelligent controller to control the whole system of the air conditioner. According to the variation of environment temperature, the intelligent controller can automatically detect, operate and record the whole system’s operating time, power consumption, event and historical data. It can store 100 event records and 1280 historical data records, and can enquire 256 days’ daily record information. The product is widely applied in telecom cabinet, small and medium sized telecom room, UPS room, outdoor base station room, etc.
    2.Features
    (1)Strong adaptability
    (2)High intelligence
    (3)High precision
    (4)High reliability
    (5)Low noise
    (6)Low energy consumption
    (7)With 4 way switching value detection
    (8)With 1 way room air conditioner control
    (9) Voltage input range: 220VAC±25% 50/60Hz
    (10) With dry contact alarm output
    3.System Principle Diagram
    TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station
    Diagram 1: System Principle Diagram
    4.Standard Compliance 
    StandardDescription
    GB/T 17626.7-1998Electromagnetic compatibility
    GB4706.1Safety of household appliance and electrical appliance with similar use.
    GB4798.1Environmental conditions existing in the application for electric and electronic products - storage
    GB4798.2Environmental conditions existing in the application for electric and electronic products - transportation
    GB4798.3Environmental conditions existing in the application for electric and electronic products - usage

    5.Technical Parameters



    Environmental Performance

    working environmental temperature-20°C ~ 55°C
    storage working temperature-50°C ~ 70°C
    working humidity≤95%
    Thermal Performancerated cooling capacity

    800W(L35 L35)

    heating input power300(optional)

    Electrical Performance

    rated input current

    2.35A(L35 L35)

    rated input power

    517W(L35 L35)

    input voltage

    AC220V/50Hz

    (187V ~ 264V)


    TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station

    Diagram 2: Dimension Diagram


    6. Installation and Electrical Wiring
    6.1 Preparation Before Installation
    (1) Prepare the tools in the following table “Installation And Maintenance Tools”.
    (2)Check the air vents to ensure there’s no unnecessary items on the vents.
    6.2 Installation And Maintenance Tools
    Tools NameFunction
    Cross ScrewdriverFix air conditioner.
    Small Slotted ScrewdriverWire power supply port on the panel
    Wire StripperWire stripping
    Wire CrimperCrimp power supply for equipment
    MultimeterCheck the wiring to ensure it’s correctly connected and without short circuit.
    Clamp MeterTest operating current of the air conditioner
    6.3 Installation Steps
    (1)Make sure the air conditioner is not connected with power.
    (2)Fix the air conditioner according to the Dimension Diagram.
    (3)Strip the insulation of the power supply wire, and crimp the terminal.
    (4)Connect the wires according to the Electrical Wring Diagram.
    (5)After finishing the wiring, use the multimeter to check if the electric circuit is normal. Then connect the air conditioner with power supply, and use clamp meter to test the operating current.
    Note: Make sure to disconnect all the power supply to the air conditioner before installation. Choose proper wire diameter and test operating current according to the technical parameters of the air conditioner.
    6. 4 Electrical Wiring Diagram
    TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station
    Diagram 3 Electrical Wiring Diagram
    Wiring Ports:
    L N PE : power supply port (voltage input: 220VAC±25% 50/60Hz)
    A+ B- GND : communication port
    AL1 AL2: general alarm output port
    F+ F- : direct ventilation output port
    N : not connected pin
    7. After mechanical installation and electrical installation are finished, check the installation items.
    (1)Make sure the air conditioner is firmly installed.
    (2)Check the electrical installation circuit, and ensure it doesn’t have short circuit.
    (3)Check the air outlet, air inlet, internal fan and external fan of the air conditioner, and ensure they don’t have any odds and ends.
    (4)Connect the air conditioner to power supply, and test the power supply (voltage input: 220VAC±25% 50/60Hz), operating current 1A±4%.
    8. System Control
    8.1 Control Board
    (1)Technical Parameter
    a.2×16 Chinese/English shift LCD display, user friendly;
    b.Simultaneously display temperature and humidity inside the box and communication room temperature;
    c.Temperature measurement accuracy: 0.1 °C; humidity measurement accuracy:5%;
    d.Can store 180 days’ daily event record, 1 record every day;
    e.Daily highest temperature, lowest temperature, average temperature
    f.Daily event record;
    g.Save the former day’s daily data at 0:00 every day; Can query 180 days’ daily record information;
    h.RS485 communication,RTU-Modbus protocol, support remote detection and control;
    i.Controllable air conditioner quantity:2 sets. 1 set of air conditioner for communication room, and 1 set of small air conditioner for thermostatic box.
    j.Control mode: pulse (Non dry contact air conditioner), conducting (dry contact air conditioner)
    k.Real-time control air conditioner on/off
    l.Power supply: AC85V~265V/50HZ;
    m.Power consumption:≤5W;
    n.Working environment: -30°C~70°C;<90%RH;
    o.Installation method: guide rail,hanging;
    p.Dimension(L*W*H):150mm×190mm×45mm
    (2)Operating Instruction
    It uses English interfaces, which can be operated easily. All the operations can be realized with four buttons. The following is the control board diagram:
    TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station
    Diagram 4 Control Board Diagram
    8.2 Buttons
    PgDn:page down button, confirm button.
    Press once and release the button, page down;
    A long press on the button, enter or exit parameter status;
    At operating status: can select three display interfaces;
    At parameter status: revise, confirm and parameter page down button; a long press on the button to exit parameter status.
    ▲:increasing parameter revision. Page down button for event query.
    ▼:decreasing parameter revision. Page up button for event query.
    PgUp: page up button; the function is oppose to PgDn operation.
    8.3 Operating Interfaces
    The controller includes four types of working modes: operating mode, parameter mode, manual operating mode, and query mode.
    (1) Operating Mode:
    The mode is normal working mode. There are three operating interfaces which can be selected. The three interfaces display different content. When they are not selected, the interfaces will automatically shift. Press the button “PgDn” to select next display interface; press the button “PgUp” to select the previous display interface.
    Interface 1:
    Line 1: temperature and humidity inside the thermostatic box (or area I);
    Line 2: box air conditioner status, real time clock;
    ※ ------- cooling start sign;
    ☼ ------- heating start sign;
    ♂ ------- hydrogen exhaust,/direct ventilation sign;
    -- ------- compressor/ heater stop working.
    Interface 2:
    Line 1: temperature and humidity inside the communication room (or area II);
    Line 2: cabinet air conditioner status, real time date;
    ※------- cabinet air conditioner start sign;
    -- ------- cabinet air conditioner off sign.
    Interface 3:
    Circularly display current alarms;
    When multiple alarms occur, it will display each alarm information circularly.
    (2)Parameter Mode:
    At operating status, long press on the button”PgDn” for around 3 seconds, or press the button”PgUp” at interface 1, to enter parameter mode.The first entered interface is the main menu interface, see the following diagram.

    TC06-160JFL/01,1600W AC220V Air Conditioner,For Outdoor Telecom Shelter/Room/Base Station

    Press the button “▲”, “▼” to choose corresponding parameter group; Press ”PgDn” to enter corresponding parameter group; Press ”PgUp” to return to operating mode. The parameters selection includes:
    (a) Observation Parameter (Apar Watch)
    (b) Control Parameter Revision (Cpar Update)
    (c) Basic Parameter Revision (Bpar Update)
    (d) Manual Operation (A/M Select)
    (e) Event Query (Event Query)
    (f) Return To Operating Mode (Return)
    (a)Observation Parameter Group (Apar):
    Enter the interface to check some parameters which can’t be checked at operating mode, see “9 Parameters”.
    At parameter mode: on the left of line 1 is Parameter No. (PAnn); on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
    (b) Control Parameter Group (CPar):
    Enter the interface to observe or revise the parameters which can be revised, see “9 Parameter”.
    At parameter mode: on the left of line 1 is Parameter No. (PCnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
    (c) Basic Parameter Group (BPar):
    Enter the interface to observe or revise the parameters which can be revised, see “9 Parameter”.
    At parameter mode: on the left of line 1 is Parameter No. (PBnn), on the right of line 1 is parameter value. Line 2 shows the remark of the parameter.
    (d) Manual Operation:
    Enter the interface to select “Cool”, “Heater”, “Air”, “Initpar”, “Aoauto” to conduct manual start and stop operation.
    (e) Event Query (Query):
    Enter query mode

    Specification sheet


    Place of Origin: Shenzhen, China (Mainland)Rated Cooling Capacity : 800W
    Brand Name: CYNRINRated Heating Capacity:500W(optional)
    Model: CCA008SADimension: H×W×D 352*175*583mm
    Product Name: Outdoor Cabinet Air ConditionerInput Voltage: AC220V/50Hz
    Certification: ISO9001, CE, 3C,Rated Input Current: 2.2A
    Cover Material: galvanized steelRated Input Power: 484W
    Color: greyWorking Temperature: -20°C ~ +55°C
    Protection Level: IP55Noise: ≤64dB
    Installation Mode: door mountedRefrigerant: R410a
    Support OEMCooling Method: compressor, active cooling


    Product details




    Dimension Diagram: H×W×D: 352*175*583mm




    • Remote measuring, remote communication, remote control, which can realize multiple automatic protection and comprehensive self-testing function.
    • Strict process control and famous brand components to ensure high quality and reliability of this product
    • Fit for harsh condition (T3),R134 a refrigerant
    • Multiple self-protection design, RS485 communication port (MODBUS-RTU protocol)
    • LED display, all the setting can charge at the field.
    • The heating function is optional
    • Dry contact alarm output, NO/NC optional
    • Anti-theft design, without the protection cover.

    Installation Diagram






    Application


    The products are widely used in

    • telecommunications,
    • electric power
    • industrial automation
    • rail transit
    • automobiles
    • CNC machine tools and other fields.
    • Indoor and Outdoor Battery Cabinet
    • Wireless Indoor and Outdoor Cabinet
    • Indoor and Outdoor Hybrid Base station

    Payment & Shipping Terms:


    Minimum Order Quantity:1 set
    Price:negotiation
    Payment Terms:T/T, L/C, etc
    Supply Ability:1,0000 sets per month
    Delivery Time:10-15 working days
    Packaging Details:carton + wooden case + pallet


    FAQ


    1. Q: How about the air cooler material?

    A: It makes by 100% new plastic, pure copper for motor.


    2. Q: What voltages you can do, could you make special voltages?

    A: we can make DC48 and all AC voltage products for you.


    3. Q: I want to use our own brand, is it OK?

    A: It is possible, we supply the OEM products too.


    4. Q: How about the warranty?

    A: All the unit warranty is one year.


    Quality 800 Watt Outdoor Cabinet Air Conditioner For Outdoor Telecom Shelter / Base Station for sale
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Cynrin Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0