Home > Plastic Products >

Led lights Spectrum Analysis Testing system

Categories led lights test instruments and machine
Place of Origin: Shenzhen,China
Brand Name: LEADSMT
Certification: CE
Model Number: X-8
Power: Electronic
MOQ: 1 Set
Price: USD 100-15000
Packaging Details: Plywood case and film
Delivery Time: 20 days
Payment Terms: TT,30% in advance ,the balance before shipping
Supply Ability: 10 sets/month
Usage: Spectrum testing
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    Led lights Spectrum Analysis Testing system

    1.X-8 SPETRUM ANALYSIS SYSTEM


    1.rapid scanning technology, greatly improve the measurement speed, full spectrum scanning fastest time 1s. Using spectral integral technology, achieve higher luminous flux measurement precision and linearity.

    2.monochromator spectrometer. Photomultiplier tube and other core components for the international famous brand high testing precision, high sensitivity, low stray light.

    2) the higher luminosity measurement spectra method was adopted to realize flux test precision. Photometric detector V (lambda) match of national level, the software embedded detector V (lambda) matching data.

    S basic measurement functions:

    1) to test relative spectral power distribution,P(λ) chromaticity coordinates,(x, y), (u, v) dominant wavelength λd, peak wavelength λp, spectral purity Pe, Correlated color temperature ,(CCT) color rendering indexRa;Ri(i=1--14), spectrum half width Δλ, luminous flux (integral), radiation power, the red rate R%, the color tolerance, the parameters such as temperature, satisfies the requirement of CIE international commission on illumination light and color measurement.

    2) EPS software can automatically describe all kinds of light source light flux after starting/power/voltage/current curve of change over time.

    3)the main technical indicators:

    Items

    Statistic

    Notice

    Wavelength measurement range

    380nm-780nm


    Wavelength accuracy

    More or less 0.5nm


    Wavelength repeatability

    More or less 1.5nm


    Chromaticity coordinates(x,y) accuracy

    More or less 0.003mm

    Under standard light source A

    Spectrum sampling interval

    5nm.1nm ,0.1nm


    Photometric system accuracy

    Class one


    Corelated color temperature measurement range

    1000k -100000k


    Corelated color temperature measurement accuracy

    More or less 0.3%

    Under standard light source A

    Luminous flux measurement range

    0.01lm~200000lm

    With suitable integrating sphere

    Color tolerance accuracy

    More or less 0.5


    Main wavelength range

    380nm-780nm


    Main wavelength accuracy

    More or less 0.2nm


    Color rendering range

    0-100

    More or less(0.3%+0.3)

    Temperature measurement range

    -20℃~80℃

    ±0.5℃

    Detector

    2048 unit line array CCD


    Testing time

    9ms-600ms


    Fiber

    SMA905


    Computer connector

    USB 2.0


    2. 1.5m long optical fiber


    Use for optical signal transmission between spectral analysis system and integrating sphere with high performance.

    3.Φ0.30m special led Integrating sphere and 1.2m integrating sphere


    Integrating sphere spraying process is good, high spectral reflectance, diffuse good performance, good stability for a long time, easy to clean, not yellow;

    Design in accordance with international standards, the ball can be loaded within two feet four feet/upright type LED lamp holder, it can realize the LED inside the ball 4 PI test. Integrating sphere side open Φ 60 mm hole and jig interface,use LED 2 PI outside of the ball test method ,the adapter supplier of various LED fixture (SMDLED, HPLED, etc.). Supplier provide free test is suitable for the 2 PI method Φ 30 high power LED (one) common fixture one only.

    the ball inside the lamp holder: E40, match [E40 transfer E27, E14 transfer E27, E27 turn GU10 (vertical)], G13 / G5 (level) .

    Functions of the spheres :

    together with the spectral analysis system or photometer use for light luminosity chromaticity parameters testing systems.

    way to open the door: unilateral rotating wheel/rail support type manually open and close;

    4.General standard Light source for calibration (3000K/2856K Spectrum Power distribution /lumin Flux)


    Original OSRAM lamp beads 6 v / 10 w ,24V/50W halogen lamp, each one piece used for spectral analysis system of color temperature (spectrum) calibration and photometer flux calibration (dissemination). High stability, high reproducibility, value can be traced back to the China metrology institute (NIM).


    5.Led chips testing fixtures


    Can test normal leds like 2835,3528 ,5730 0805 and high power leds (in the small sphere) .

    6.wp3005 precise digital display DC current and voltage stabilized supply


    1) voltage stability: ≤ 5×10-5 ,reading + 2 mv

    2) voltage range: 5 v / 10v / 25 v / 50 v;

    3) current stability: ≤ 1×10-4, readings +0.5mA ;

    4) range of ammeter range: 0.5A/1A/2.5A/5A

    5) voltage resolution :0.0001 V, (0.0000 V ~ 3.000 V); 0.001 V, (3.000 V ~ 50.000 V);

    6) voltage accuracy: + / - (0.02% reading+ 0.01%reading range + 2 words);

    7) current resolution: 0.0001 A, (0.0000 A to 0.0000 A);

    8)current accuracy: + / - (0.02%reading + 0.01%reading range + 2 words);

    9) maximum output power: 150 VA

    10)The maximum output voltage : 30 V

    11) the largest output current: 5 A


    7. UI2012 AC-DC electric parameter measurement instrument


    our window at the same time display voltage, current, power, power factor, with RS - 232 communication function;

    main technical indicators:

    1) can measure ac, dc, ac/dc signal;

    2) current and power with maximum,minimum limit alarm, especially suitable for the production line extensive testing,

    3) voltage range: AC: 5 ~ 600 v, DC: 1 ~ 600 v, current range: AC & DC: 0.005 ~ 20.00 A, range automatic conversion;

    4) accuracy: + / - (0.4%reading +0.1% reading range + 1 word)

    8.PDF-500 Precision frequency test power supply


    FDP series precision frequency test power supply is a kind of high power, low distortion, high stability of the power frequency pure sine wave power supply, integration of the source table. Adopt AC - DC - AC frequency conversion and digital waveform synthesis and waveform feedback, the integral period sampling of high-speed high precision, zero output impedance, isolated floating output, voltage current abnormal, and overheating protection, boot current limit and a series of advanced technology to ensure the accuracy of the power, pure nature, reliability and security. Use advanced 32-bit MCU control and measurement, RS - 232 communication can realize intelligent programmable output operations.

    the main technical indicators:

    1. The input voltage, AC 220 v/AC 110 v (internal change jumper wire), plus or minus 10% 1 phi 2 w 50/60 Hz

    2. The output voltage: 0 ~ 150 v or 0 ~ 300 v two notches

    3. The output voltage temperature coefficient: plus or minus 0.2% / ℃

    4. The total harmonic distortion: ≦ 0.2% (at 50/60 Hz) (ats Resister Load, PF = 1, THD -r measurement)

    5. The output line: 1 phi 2 w

    6. The output capacity: 500 VA

    7. The largest output current: 120 v / 4.2 A; 240 v / 2.1 A.

    test must meet the following conditions: AC power supply voltage plus or minus 5%, THD ≦ 2%, plus or minus 5% frequency;

    8.Power stability factor: + / - 0.2% (ACV + / - 10%; THD ≦ 2%; frequency + / - 5%) (@Voltage output 80% Full scale , LOAD = 0 ~ 50%; PF = 1)

    9. The output frequency: 45 Hz ~ 65 Hz

    10. The frequency resolution(realization): 0.01 Hz;

    11. The frequency accuracy: + / - 0.05%

    9.. photoelectric color measurement system cabinet (with door and panel)

    international standard open file size, the high quality cold rolling steel plate, the grey tones, well made. The X - 8, WP3005, UI2012, FDP500 in this standard cabinets, make a complete set of photoelectric instrument as a whole the beauty is generous. Save a space, convenient reading operation, good resistance to electromagnetic interference. Cabinet install ac/dc switch, convenient wiring, easy to control operations. With excellent dustproof glass door, in line with international trends.



    Contact ;

    1.Email:peter.huang187machines@gmail.com

    2.Skype: peter.huang187

    3.Tel:0086-13610497541

    Quality Led lights Spectrum Analysis Testing system for sale
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Leadsmt Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0