Sign In | Join Free | My fnxradio.com
fnxradio.com
Products
Search by Category
Home >

HAROWE 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15

Categories Leine linde
Place of Origin: GERMANY
Brand Name: HAROWE
Model Number: 15BRCX-602-F15B/15
Certification: CE
MOQ: 1pcs
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 100pcs/week
Delivery Time: in stock
Packaging Details: carton
HAROWE: HAROWE
15BRCX-602-F15B/15: 15BRCX-602-F15B/15
GERMANY: GERMANY
Temperature: 20-90
wire: wire
dimension: 90mm
color: black
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    • Product Details
    • Company Profile

    HAROWE 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15

    Backplane bus interface ERROR Error display LED (red)
    ④ Supply voltage via power supply element PWR LED for power supply (green)
    Equipotential bonding cable (optional)
    Figure 3-2 Block diagram and pin assignment for voltage measurementThe example in the following
    figure shows the pin assignment for current measurement with

    4-wire transducers.① Connector 4-wire transducer CHx Channel or 8 x channel status (green/red)
    ② Analog-to-Digital Converter (ADC) RUN Status display LED (green)
    ③ Electrical isolation ERROR Error display LED (red)
    ④ Backplane bus interface PWR LED for power supply (green)
    ⑤ Supply voltage via power supply element
    ⑥ Equipotential bonding cable (optional)
    Figure 3-3 Block diagram and terminal assignment for 4-wire transducer for current measurementThe example in the following figure shows the pin assignment for current measurement with
    2-wire transducers.
    Connector 2-wire transducer CHx Channel or 8 x channel status
    (green/red)
    ② Analog-to-Digital Converter (ADC) RUN Status display LED (green)
    ③ Electrical isolation ERROR Error display LED (red)
    ④ Backplane bus interface PWR LED for power supply (green)
    ⑤ Supply voltage via power supply element
    ⑥ Equipotential bonding cable (optional)
    Figure 3-4 Block diagram and terminal assignment for 2-wire transducer for current measurementThe module is set to voltage measuring type with measuring range ±10 V by default. You
    need to reassign the module parameters with STEP 7 if you want to use a different
    measuring type or range.
    The following table shows the measuring types and the respective measuring rangeSee Appendix Representation
    of analog
    values in voltage
    measuring ranges
    (Page 62).
    Current 2WMT
    (2-wire transducer)
    4 mA to 20 mA See Appendix Representation
    of analog
    values in the current
    measuring ranges
    (Page 63).
    Current 4WMT
    (4-wire transducer)
    4 mA to 20 mA
    0 mA to 20 mA
    ±20 mA
    Deactivated -
    The tables of the input ranges, overflow, undershoot range, etc. are available in appendix
    Representation of analog values (Page 60).The AI 8xU/I HF is usually already integrated in the hardware catalog of STEP 7 (TIA Portal).
    In this case, STEP 7 (TIA Portal) checks the configured properties for plausibility during
    configuration.
    However, you can also assign parameters to the module by means of a GSD file and the
    configuration software of any provider. The module does not check the validity of the
    configured properties until after the configuration has been loaded.
    When you assign the module parameters in STEP 7, you use various parameters to specify
    the module properties. The following table lists the configurable parameters. The effective
    range of the configurable parameters depends on the type of configuration. The following
    configurations are possible:

    Central operation with a CPU
    ● Distributed operation on PROFINET IO in an ET 200MP system
    ● Distributed operation on PROFIBUS DP in an ET 200MP system
    When assigning parameters in the user program, use the WRREC instruction to transfer the
    parameters to the module by means of data records; refer to the section Parameter
    assignment (Page 50).
    The following parameter settings for the channels are possible:
    Table 4- 1 Configurable parameters and their defaultsMissing supply voltage
    L+
    Yes/No No Yes Channel 1) Module 3)
    • Overflow Yes/No No Yes Channel Module 3)
    • Underflow Yes/No No Yes Channel Module 3)
    • Wire break Yes/No
    (Voltage: 1 V to 5 V
    Current: 4 mA to
    20 mA)
    No Yes Channel Module 3)
    • Current limit for wire
    break diagnostics 2)
    1.185 mA or 3.6 mA 1.185 mA Yes Channel -• Measurement type See section Measuring
    types and ranges
    (Page 25)
    Voltage Yes Channel Channel
    • Measuring range ±10 V Yes Channel Channel
    • Operating mode Standard
    Fast
    Standard Yes Channel --- 4)
    • Interference frequency
    suppression
    400 Hz
    60 Hz
    50 Hz
    10 Hz
    50 Hz Yes Channel Module
    • Smoothing None/low/medium/hi
    gh
    None Yes Channel Channel

    Quality HAROWE 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15 15BRCX-602-F15B/15 for sale
    Send your message to this supplier
     
    *From:
    *To: Guang Zhou Lai Jie Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0