Sign In | Join Free | My fnxradio.com
fnxradio.com
Products
Search by Category
Home > Battery Testers >

39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output

Categories Secondary Injection Test Set
Brand Name: HAOMAI
Model Number: RELAYSTAR-1600
Certification: ISO9001:2015, Type Test Report, Calibration Report
Place of Origin: China
MOQ: 1 set
Price: negotiation
Payment Terms: T/T
Supply Ability: 400 sets per month
Delivery Time: 5-10 working days
Packaging Details: Transport Case + Plywood Case
Product name: Relay Tester, Relay Test System, Protection Relay Test Set
6-phase current output: 6×0…40A
6-phase voltage output: 6×0…150V
AC Output Accuracy: ≤0.1%
Embedded IPC with LCD screen: Available
End-to-End Test: via built-in GPS
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
Submit Buying Request
  • Product Details
  • Company Profile

39.68lb Current Secondary Injection Test Set Multimode 6x150V Voltage Output

High Power 6-phase Secondary Injection Test Set


Model: RELAYSTAR-1600

The RELAYSTAR-1600 is 6-phase secondary injection test set for testing all generations and types of protection relays, which can output 6-phase current(6x0…40A) and 6-phase voltage (6x0…150V). Its powerful current source(6x0…40A, 6x300VA; 1x0…240A, 1x1000VA) is capable of testing high-burden electromechanical relays with very high power demands.

6-phase secondary injection test set RELAYSTAR-1600 can be synchronized to perform end-to-end testing with the test sets allocated in different substations through its in-built GPS.

The local software system of 6-phase secondary injection test set RELAYSTAR-1600 is designed based on Windows system. It can either be operated by embedded industrial PC with 10.4-inch TFT LCD screen or by test software running on a PC.


Main Features:

1) 6-phase current(6×40A) + 6-phase voltage(6×150V) output

2) Embedded industrial PC with 10.4-inch LCD screen

3) Both local test and PC remote test available

4) High performance linear power amplifier

5) In-built monitoring and recording

6) End to end test with in-built GPS

7) Intelligent self-protection

8) Abundant test modules


Technical Data

Current Generator

Setting range6-phase AC(L-N)6x0…40A
3-phase AC(L-N)3x0…80A
1-phase AC(LL-LN)1x0…240A
DC(L-N)6x0…±20 A
Power6-phase AC(L-N)6x300VA at 40A
3-phase AC(L-N)3x450VA at 80A
1-phase AC(LL-LN)1x1000VA at 240A
DC(L-N)6x120VA at 20A
AccuracyAC: ±1mA(≤0.2A), ≤0.1% (0.2~40A)
DC: ±5mA(0.2~0.5A), ≤0.2% (0.5~20A)
Resolution1mA

Voltage Generator

Setting range6-phase AC(L-N)6x0…150V
3-phase AC(L-N)3x0…300V
DC(L-N)6x0…±175V
Power6-phase AC(L-N)6x80VA at 150V
3-phase AC(L-N)3x100VA at 300V
DC(L-N)6x80VA at 175V
AccuracyAC: ±2mV(0.2~2V), ≤0.1% (2~150V)
DC: ±10mV (0.5~5V), ≤0.2% (5~175V)
Resolution1mV

Auxiliary DC Supply

Voltage range110V/220V(max.1.5A)
Powermax.165VA/330VA

Binary Inputs

Number10
Input characteristicsidle contact or potential-free contact
Threshold characteristics“0”:0~6V; “1”:12V~250V
Max. measuring time999999.999s
Time accuracy±1ms
Time resolution1ms

Binary Outputs

Number8
Typeidle contact
Break capacity250VAC/0.5A, 250VDC/0.2A

In-built Monitoring and Recording

Monitoringcurrents and voltage outputs
Recordinganalog outputs, binary inputs/outputs status
Modereal time monitoring, no external wiring is required
Recording lengthunlimited (until the internal memory is full)

General Generators

Frequencyrange: 0~1200Hz
accuracy:<1mHz(0~65Hz);<10mHz(65~450Hz);<20mHz(450~1200Hz)
resolution: 0.001Hz
Phaserange: -360° ~+360°
accuracy: 0.1°
resolution: 0.01°
Harmonicsuperposition order: 2~24 times
distortion: ≤0.5%

Power Supply

Nominal input voltagecustomized (AC 220V/230V/120V±10%, 1-phase)
Nominal frequency50/60 Hz
Rated current10A at 230V / 12A at 115V
Connectionstandard AC socket (IEC 60320)

Environmental Conditions

Operation temperature0 ... +50 °C (+32 ... +122 °F)
Storage temperature-25 ... +70 °C (-13 ... +158 °F)
Humidity rangerelative humidity 5 ... 95 %, non-condensing
VibrationIEC 60068-2-6(20m/s2 at 10 ... 150 Hz)

Miscellaneous

Weight18kg(39.68 lb)
Dimensions (W x H x D, without handle)420×360×210mm(16.54x14.17x8.27 in)
Connection port2 USB2.0 ports, 1 Ethernet port

Safety Standards, Electromagnetic Compatibility

EMCThe product adheres to the electromagnetic compatibility (EMC) Directive 2004/108/EC(CE conform)
IEC 61326-1; IEC 61000-6-4; IEC 61000-3-2/3
SafetyThe product adheres to the low voltage Directive 2006/95/EC(CE conform).
IEC 61010-1

6-phase Secondary Injection Test Set RELAYSTAR-1600 is an excellent choice for testing and commissioning engineers to perform protection relay testing on site.