Sign In | Join Free | My fnxradio.com |
|
Categories | Thermocouple Cable |
---|---|
Brand Name: | OHMALLOY |
Model Number: | K-HP-HP-20 |
Certification: | ISO9001-2008 |
Place of Origin: | China(Shanghai) |
MOQ: | 100meters |
Price: | negotiable |
Payment Terms: | L/C, T/T, |
Supply Ability: | 500000meters per month |
Delivery Time: | 10 days |
Packaging Details: | 100m/spool, 305m/spool, 1000ft/spool, 1000m/spool |
Material: | Chromel, Constantan |
Insulation: | PVC, Fiberglass, PTFE, silicon rubber |
Diameter: | 20 AWG |
Color: | ASTM code,ANSI code, IEC code, GB/T standard |
Company Info. |
Ohmalloy Material Co.,Ltd |
Verified Supplier |
View Contact Details |
Product List |
Type E Extension Cable Chromel / Copel Material PVC 221F Insulation
Specifications
1.Style:Extension Wire
2.Thermocouple copper wire
Thermocouple wire Classification
1. Thermocouple level (high temperature level). This type of
thermocouple wire is mainly suitable for thermocouple type K, J, E,
T, N and L and other high temperature detection instrument,
temperature sensor, etc.
2. Compensating wire level (low temperature level). This type of
thermocouple wire is mainly suitable for compensating cable and
extension wire of various thermocouples of type S, R, B, K, E, J,
T, N and L, heating cable, control cable and so on.
Thermocouple variety and index
Thermocouple Variety and Index | ||
Variety | Type | Measurement Range(°C) |
NiCr-NiSi | K | -200-1300 |
NiCr-CuNi | E | -200-900 |
Fe-CuNi | J | -40-750 |
Cu-CuNi | T | -200-350 |
NiCrSi-NiSi | N | -200-1300 |
NiCr-AuFe0.07 | NiCr-AuFe0.07 | -270-0 |
3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire
Dimensions / Tolerance mm ) : 4.0+-0.25
Color code & initial calibration tolerances for thermocouple wire:
Thermocouple Type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
CHROMEL(+) vs. Constantan(-) | E | Purple/Red | Brown | -200°C to -170°C -170°C to +250°C 250°C to +340°C 340°C+900°C | ± 1% ±1.7°C ±1.7°C ± .5% | ±1°C ±1°C ± .4% ± .4% |
Color Code & Initial Calibration Tolerance for Extension Wire:
Extension type | ANSI Color Code | Initial Calibration Tolerances | ||||
Wire Alloys | Calibration | +/- Conductor | Jacket | Temperature Range | Standard Limits | Special Limits |
CHROMEL(+) vs. Constantan(-) | EX | Purple/Red | Purple | 0°C to +200°C | ±1.7°C | ±1.1°C |
PVC-PVC Physical Properties:
Characteristics | Insulation | Jacket |
Abrasion Resistance | Good | Good |
Cut Through Resistance | Good | Good |
Moisture Resistance | Excellent | Excellent |
Solder Iron Resistance | Poor | Poor |
Service Temperature | 105ºC continuous 150ºC single | 105ºC continuous 150ºC single |
Flame Test | Self-extinguishing | Self-extinguishing |
![]() |